(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal

Model NO.: UN2000A
Size: 7inch
Weight: 2kg
Etco2: Optional
OEM: Support
Trademark: UN
Transport Package: Carton
Origin: China
HS Code: 9018193000
Model NO.: UN2000A
Size: 7inch
Weight: 2kg
Etco2: Optional
OEM: Support
Trademark: UN
Transport Package: Carton
Origin: China
HS Code: 9018193000
(UN2000A) Bluetooth Touchscreen ETCO2 Vital Sign Patient Monitor for Hospital/ICU

Model:UN2000A
Waveform:ECG and SPO2 waveforms

Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional


Priors
 
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out


Parameters

ECG

Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation


Heart Rate

Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm

SpO2

SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm

NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device. 

Temperature

Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC

EtCO2(Optional)

Measuring Range:  0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm

Printer (optional)

Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.  
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH


(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal
(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal


Payment

(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal


Shipping


Three Channels ECG Machine with Touch Screen (UN8003)


(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal



  (UN2000A) Bluetooth Touchscreen ETCO2 Vital Sign Patient Monitor for Hospital/ICU

Model:UN2000A
Waveform:ECG and SPO2 waveforms

Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional


Priors
 
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out


Parameters

ECG

Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation


Heart Rate

Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm

SpO2

SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm

NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device. 

Temperature

Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC

EtCO2(Optional)

Measuring Range:  0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm

Printer (optional)

Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.  
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH


(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal
(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal


Payment

(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal


Shipping


Three Channels ECG Machine with Touch Screen (UN8003)


(UN2000A) Portable Touchscreen Vital Sign Patient Monitor for Human/Veterinary/Animal



 

Fish Meal

Fish Meal,Protein Content Fish Meal,Protein Content Fish Meal

Feed Additives ,Choline Chloride,Corn Products Co., Ltd. , http://www.sdbiotechnology.com